A new approach to deal with sensor errors in structural controls with MR damper

dc.contributor.authorHarman, Thomas L.
dc.contributor.authorWang, Han
dc.contributor.authorLi, Luyu
dc.contributor.authorSong, Gangbing
dc.contributor.authorDabney, J. B.
dc.date.accessioned2019-10-08T16:49:38Z
dc.date.available2019-10-08T16:49:38Z
dc.date.issued2015
dc.description.abstractAs commonly known, sensor errors and faulty signals may potentially lead structures in vibration to catastrophic failures. This paper presents a new approach to deal with sensor errors/faults in vibration control of structures by using the Fault detection and isolation (FDI) technique. To demonstrate the effectiveness of the approach, a space truss structure with semi-active devices such as Magneto-Rheological (MR) damper is used as an example. To address the problem, a Linear Matrix Inequality (LMI) based fixed-order H-infinity FDI filter is introduced and designed. Modeling errors are treated as uncertainties in the FDI filter design to verify the robustness of the proposed FDI filter. Furthermore, an innovative Fuzzy Fault Tolerant Controller (FFTC) has been developed for this space truss structure model to preserve the pre-specified performance in the presence of sensor errors or faults. Simulation results have demonstrated that the proposed FDI filter is capable of detecting and isolating sensor errors/faults and actuator faults e.g., accelerometers and MR dampers, and the proposed FFTC can maintain the structural vibration suppression in faulty conditions.en_US
dc.identifier.citationHan Wang, Luyu Li, Gangbing Song, James B. Dabney and Thomas L. Harman, “A new approach to deal with sensor errors in structural controls with MR damper”, Smart Structures and Systems, Vol. 16, No. 2 (2015)en_US
dc.identifier.issn1738-1584
dc.identifier.urihttps://hdl.handle.net/10657.1/1587
dc.publisherSmart Structures and Systemsen_US
dc.relation.ispartofseriesSmart Structures and Systems;Vol. 15, No. 2
dc.titleA new approach to deal with sensor errors in structural controls with MR damperen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A new approach to deal with sensor errors in structural controls with MR damper.pdf
Size:
427.84 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections