Optimal sample preservation and analysis of CR(VI) in drinking water smaplers by high resolution ion chromatography followed by post column ractioni and UV/Vis detection

dc.contributor.authorZhang, Carl
dc.date.accessioned2020-04-17T15:22:08Z
dc.date.available2020-04-17T15:22:08Z
dc.date.issued2012
dc.description.abstractA recent study by the Environmental Working Group reported the detection of hexavalent chromium (Cr(VI)) in tap water at 31 out of 35 states investigated in the United States. Even though Cr(III) is an essential element for human diet, Cr(VI) is a potential carcinogen. Previous work has clearly identified a linear trend of increasing risk of lung cancer mortality with increasing cumulative exposure to water soluble Cr(VI). Regardless, Cr(VI) is still not regulated or monitored in drinking water in the US. There is an existing method (EPA 218.6) for the analysis of Cr(VI), however, this analytical method does not addresses detailed sample preservation techniques and optimization process to achieve lowest detection limit possible. In this study, five buffer solutions with pH of 9 and above were compared to determine the most suitable buffer to preserve Cr(VI) in drinking water samples for an extended period of time. Results showed that the five buffers responded very differently to Cr(VI)-fortified drinking water. The best preserving reagent was found to be Ammonium Hydroxide + Ammonium Sulfate (pH 9.2) and Sodium Carbonate + Sodium Bicarbonate+ Ammonium Sulfate (pH 9.7), whereas a buffer solution with Sodium Hydroxide + Sodium Carbonate (pH 11.5+) resulted in a poor chromatographic resolution. A controlled study with a fortified Cr(III) at 1 ppb was also conducted to ensure no false positive detection of Cr(VI) due to the potential oxidation of Cr(III) during sample storage. The optimal preserving reagent identified from this study was compatible with the existing EPA method 218.6 using ion chromatography followed by post column reaction, with a method quantitation limit of 0.020 ppb and matrix spike recovery of ± 10%.en_US
dc.identifier.citationEzebuiro P, Gandhi J, Zhang C, Mathew J, Ritter M, Humphery M (2012), Optimal sample preservation and analysis of Cr(VI) in drinking water samplers by high resolution ion chromatography followed by post column reaction and UV/Vis detection. J. Anal. Sci. Methods and Instrumentation. 2, 74-80.en_US
dc.identifier.urihttps://hdl.handle.net/10657.1/2260
dc.subjectHexavalent Chromium; Ion Chromatography; USEPA Method; Sample Preservationen_US
dc.titleOptimal sample preservation and analysis of CR(VI) in drinking water smaplers by high resolution ion chromatography followed by post column ractioni and UV/Vis detectionen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optimal sample preservation and analysis.pdf
Size:
8.16 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: